ABBOTT LABORATORIES, DIAGNOSTICS DIVISION -- LIDOCAINE HYDROCHLORIDE INJ.,USP,4903,7931,7939. -- 6505-00-598-6116
===================== Product Identification =====================
Product ID:LIDOCAINE HYDROCHLORIDE INJ.,USP,4903,7931,7939.
MSDS Date:12/13/1991
FSC:6505
NIIN:00-598-6116
=== Responsible Party ===
Company Name:ABBOTT LABORATORIES, DIAGNOSTICS DIVISION
Address:RT 43 AND 137
City:ABBOTT PARK
State:IL
ZIP:60064-9078
Country:US
Info Phone Num:708-937-7970/800-323-9100
Emergency Phone Num:708-937-7970/800-323-9100
CAGE:0ALT7
=== Contractor Identification ===
Company Name:ABBOTT LABORATORIES DIAGNOSTICS DIV
Address:RT 43 AND 137
Box:City:NORTH CHICAGO
State:IL
ZIP:60064-9078
Country:US
Phone:800-323-9100
CAGE:0ALT7
============= Composition/Information on Ingredients =============
Ingred Name:LIDOCAINE HYDROCHLORIDE IN AQUEOUS SOLUTION.
CAS:73-78-9
RTECS #:AN7600000
Other REC Limits:NONE RECOMMENDED
Ingred Name:AQUEOUS SOLUTION
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50=220-457MG/KG,MICE,ORAL.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTAINS LIDOCAINE HYDROCHLORIDE IN
AQU SOLN.HEALTH RELATED DATA FOR PROD BASED ON LIDOCAINE
HYDROCHLORIDE CONTENT.LOC ANESTHETIC THAT PRODUCES NUMBUNESS & THAT
AFFECTS CNS & CARDIOVASCULAR SYSTEM.CAN AFFECT FETUS(FETAL HYPOXIA
OR BRADYCARDIA)IF USED DURING LABOR/DELIVERY.INFREQUENT INDICES
DELAYED HYPERSENSITIVITY RES
Explanation of Carcinogenicity:PER
MSDS:CARCINOGENICITY:NTP/IARC/OSHA/ACGIH:NOT LISTED.
Effects of Overexposure:IN CLINICAL USE PRODUCES
NUMBNESS,LIGHTHEADEDNESS,DROWS,DIZZ,RESTLESSNESS,LOSS OF
HEARING,BREATH/SWALLOWE
DYSFUNCTION,APPREHENSION,EUPHORIA,TINNITIS,ALTERED
VISION,VOMIT,SENSATION OF HOT/COLD NUMBNESS
,TWITCHING,TREMORS,STUPOR,CONVULSIONS,UNCONSC,RESP
ARREST,HYPOTENSION,BRADYCARDIA & CARDIOVASCULAR COLLAPSE.
Medical Cond Aggravated by Exposure:SENSITIVITY TO LOCAL ANESTHETICS.
PRE-EXISTING CARDIOVASCULAR OR CENTRAL NERVOUS SYSTEM DISEASE.
======================= First Aid Measures =======================
First Aid:REMOVE FROM SOURCE OF EXPOSURE. SKIN/EYE CONTACT OCCURS FLUSH
W/COPIOUS AMTS OF WATER. IF IRRIT PERSISTS OR SIGNS OF TOXICITY
OCCUR SEEK MED ATTN. NO KNOWN ANTIDOTE. PROVIDE
SYMPTOMATIC/SUPPORTIVE, MO NITORING CARDIAC & RESP FUNCTION, CARE
AS NECESSARY.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:PER MSDS:N/A. HOWEVER USE APPROPRIATE EXTINGUISHING
MEDIA FOR SURROUNDING FIRE.
Fire Fighting Procedures:NONE.
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB WITH SUITABLE MATERIAL. FLUSH WITH
WATER.
Neutralizing Agent:NONE SPECIFIED BY MFG.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE.
Other Precautions:NONE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED.
Ventilation:NO SPECIAL PROVISIONS REQUIRED.
Protective Gloves:GLOVES TO MINIMIZE SKIN CONTACT.
Eye Protection:GOGGLES.
Other Protective Equipment:N/A.
Work Hygienic Practices:WASH HANDS AFTER HANDLING.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:WATER(APRX)
Melt/Freeze Pt:M.P/F.P Text:WATER(APRX)
Spec Gravity:WATER(APPROX)
pH:3-7
Viscosity:WATER(APPROX)
Solubility in Water:AQUEOUS SOLUTION
Appearance and Odor:CLEAR LIQUID.
Percent Volatiles by Volume:NELGIG
================= Stability and Reactivity Data =================
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NOT DETERMINED.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. AS OF REVIEW DATE OF THIS DOCUMENT (MFG'S
MSDS) THIS CHEMICAL IS NOT AN RCRA HAZ WASTE (PER 40CFR PART 261).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.